ASHING FURNACE AAF



Merek : CARBOLITE1100°C Ashing furnace (AAF)
• Maximum operating temperature 1100°C
• Chamber capacities of 3, 7 or 18 litres
• Robust mullite muffle design of 3 & 7 litre models and silicon carbide tiles of 18 litre model offer strong resistance to carbon build up and chemical attack
• Constant airflow of 4-5 volume changes per minute ensures rapid combustion
• Pre-heated airflow to maintain excellent temperature uniformity
• 3 & 7 litre models supplied with inconel tray & handle for easy loading/unloading
• Tall chimney for fume exhaust by convection
• Vertical counter-balanced door keeps hot door insulation away from operator
• Postive break door safety switch isolates chamber from power supply, when the door is opened
• Double skinned construction allows convection air flow to cool the outer case, to conform to EN61010 safety standard
• Choice of PID controller or programmers
• Pictured left are 3 & 7 litre models
Model AAF 11/3 AAF 11/7 AAF 11/18
Max operating temp (‘C) 1100’C
Internal dimensions 90 x 150 x 250 90 x 170 x 455 235 x 196 x 400 mm ( H x W x D )
External dimensions excluding chimney
580 x 370 x 485 650 x 430 x 740 705 x 505 x 675 mm
Nominal heat up time (minutes) 80* 110* 60
Uniform envelope 5’C 50 x 100 x 100 55 x 140 x 260 Not available
Holding power @ 1000’C (W) 1200 2300 3500
Maximum power 2000 -3900 -7000 W
Temperature sensor Type K thermocouple
Net weight (kg) 22 63 70
Specifications
• Maximum operating temperature 1100°C
• Chamber capacities of 3, 7 or 18 litres
• Robust mullite muffle design of 3 & 7 litre models and silicon carbide tiles of 18 litre model offer strong resistance to carbon build up and chemical attack
• Constant airflow of 4-5 volume changes per minute ensures rapid combustion
• Pre-heated airflow to maintain excellent temperature uniformity
• 3 & 7 litre models supplied with inconel tray & handle for easy loading/unloading
• Tall chimney for fume exhaust by convection
• Vertical counter-balanced door keeps hot door insulation away from operator
• Postive break door safety switch isolates chamber from power supply, when the door is opened
• Double skinned construction allows convection air flow to cool the outer case, to conform to EN61010 safety standard
• Choice of PID controller or programmers
• Pictured left are 3 & 7 litre models
Model AAF 11/3 AAF 11/7 AAF 11/18
Max operating temp (‘C) 1100’C
Internal dimensions 90 x 150 x 250 90 x 170 x 455 235 x 196 x 400 mm ( H x W x D )
External dimensions excluding chimney
580 x 370 x 485 650 x 430 x 740 705 x 505 x 675 mm
Nominal heat up time (minutes) 80* 110* 60
Uniform envelope 5’C 50 x 100 x 100 55 x 140 x 260 Not available
Holding power @ 1000’C (W) 1200 2300 3500
Maximum power 2000 -3900 -7000 W
Temperature sensor Type K thermocouple
Net weight (kg) 22 63 70
Specifications